AIR COMPRESSOR PUMP 3HP 2.2KW PISTON TWIN CYLINDER AIR COMPRESSOR

Twin screw air compressor overload shutdown

Twin screw air compressor overload shutdown

Try to turn the compressor by hand. It should be possible to turn it around. It should turn around smoothly, without any ‘hiccups’ (be sure to completely shut down the air compressor!). Check the isolation of the motor winding. [pdf]

Screw air compressor pump head produces gas slowly

Screw air compressor pump head produces gas slowly

Either an electrical problem, or the compressor has tripped on a safety device. Check supply power. Check for errors on display. Check emergency stop is out. Check and reset the overload relay. If it’s a new installation, check the phase sequence. Ambient temperature too high or not enough ventilation. [pdf]

Wenheng twin screw air compressor maintenance

Wenheng twin screw air compressor maintenance

It should turn around smoothly, without any 'hickups' (be sure to completely shut down the air compressor!). Check the isolation of the motor windings. Should be in the mage-ohms (you need an isolation tester / high voltage ohm meter for this). Check the voltage when the compressor is running. [pdf]